【Voltage Compatibility】
When using electrical appliances, please note that they are designed for Japanese voltage specifications (90-110V), so if you use them with a different voltage, it may cause a malfunction.
【Plug Type】
Our products use Japanese plug types (A or B type).
Please use a conversion adapter if necessary.
【Important Note on Transformers and Adapters】
A transformer adjusts voltage to match your device’s requirements.
A conversion adapter only changes the plug shape and does not adjust voltage.
Using only a conversion adapter without a transformer may result in damage to the product.
【Liability】
We are not responsible for malfunctions or damages caused by improper use, such as operating the product without a transformer.
----------------------------------------------------------------------
ACV: [Range] 200V, 600V [Resolution] 0.1V (~200V), 1V (~600V), [Accuracy] ±(1.2%rdg+10dgt)
DCV: [Range] 200mV, 2V, 20V, 200V, 600V, [Resolution] 0.1mV (~200mV), 0.001V (~2V), 0.01V (~20V), 0.1V (~200V), 1V (~600V), [Accuracy] ±(0.5%rdg+2dgt) ±(0.8%rdg+2dgt) /600V
DCA: [Range] 200μA, 2mA, 20mA, 200mA, 10A [Resolution] 0.1μA (~200μA), 0.001mA (~2mA), 0.01mA (~20mA), 0.1mA (~200mA), 0.01A (~10A), [Accuracy] ±(1.0%rdg+2dgt) ±(1.5%rdg+2dgt) ±(3.0%rdg+5dgt) /10A
Ω: [Range] 200Ω, 2kΩ, 20kΩ, 200kΩ, 20MΩ [Resolution] 0.1Ω (~200Ω), 0.001kΩ (~2kΩ), 0.01kΩ (~20kΩ), 0.1kΩ (~200kΩ), 0.01MΩ (~20MΩ), [Accuracy] ±(0.8%rdg+4dgt) /200Ω ±(0.8%rdg+2dgt) ±(3.0%rdg+3dgt)
Operating principle: double integral method
Display/sampling/range switching: 3.5 digit LCD display, maximum 1999 counts, 3 times/second, manual range
Power supply: 9V dry battery x 1
Dimensions/Weight: W76 x H150 x D38mm, approximately 215g
Accessories: Instruction manual, test leads
Options: Test lead: ATL-2