Soil Temperature Humidity Sensor High Accuracy Digital Soil Temp Moisture Sensor Probe DC3.3V
Түс
Суреттегідей






Сипаттама
Feature: 1. MEASURING RANGE: Soil temperature and humidity sensor probe, with a temperature range of ‑20‑100℃ and accuracy of ±0.2℃, a humidity range of 0‑100%RH and accuracy of ±2%RH. 2. HIGH ACCURACY: The soil temperature and humidity sensor adopts an excellent chip with powerful functions, high accuracy, and a resolution of up to 14 bits. 3. APPLICABLE SCENE: Used for machine room monitoring, weather station, warehouse, construction site, concrete test block detection, greenhouse, flower planting, etc. 4. MULTIPLE FUNCTION: The voltage is 3.3V, a 100nF decoupling capacitor is connected between the internal power supply and the grounding, with full calibration and digital output. 5. 300CM LONG CABLE: This sensor has a 300cm extension cable, which is not limited by location and is easy to carry and install, with high reliability and long term stability. Specification: Item Type: Soil Temperature Humidity Sensor Model: FS400 SHT31 Working Current: <15mA Humidity Accuracy: ±2%RH Temperature Accuracy: ±0.2℃ Temperature Measurement Range: -20-100℃ Humidity Measurement Range: 0-100%RH Comm Interface: I²C Working Condition: -20-90℃, 0-99%RH Storage Condition: -20-80℃, 0-95%RH Material: Stainless Steel, Plastic Cable Length: Approx. 300cm / 118in Product Features: 1. Digitization, with a resolution of up to 14 bits; 2. Internal self calibration, no calibration required; 3. The close combination of temperature and humidity is convenient for dew point measurement; 4. Anti rain, dust, rust, high reliability and long term stability. Package List: 1 x Soil Temperature Humidity Sensor Note: The relative humidity of air is a function of temperature, and air temperature has a great impact on relative humidity. Various compounds such as acids, alkalis, and salts have a significant impact on the physical properties of water steam. The following precautions should be taken when using: 1. The temperature and humidity sensor should be installed in a place where the temperature is relatively stable and can best represent the measured ambient temperature and humidity. 2. Avoid installing in places with drastic temperature changes. 3. Avoid installing in areas with intense air flow. 4. Avoid installing in dead corners where air does not flow. 5. Avoid using in salt spray environments. 6. Avoid using in corrosive gas environments. Working Conditions: The sensor performs normally within the recommended operating range, please refer to Figure 1. Long term exposure to conditions outside the normal range, especially when humidity exceeds 80%, may cause temporary signal drift (drift+3%RH after 60 hours). After returning to normal operating conditions, the sensor will slowly self recover to the calibration state. Prolonged use under abnormal conditions can accelerate the aging of the product.